PreviewHistory

Lighting Plan Generator

Upload a floor plan and get a lighting plan that layers ambient, task and accent light room by room, with fixtures, switching zones and light levels you can actually read.

Apartment Floor Plan to Layered Lighting Plan
Apartment Floor Plan to Layered Lighting Plan (Before)
BeforeAfter

Before & After

Before & After Transformations

Drag across each transformation to inspect structural fidelity, or load any instruction directly into the studio above.

Apartment Floor Plan to Layered Lighting Plan
Apartment Floor Plan to Layered Lighting Plan (Before)
BeforeAfter

Apartment Floor Plan to Layered Lighting Plan

Create a layered lighting plan for this apartment with ambient downlights, kitchen pendants, under-cabinet LEDs, vanity lights and accent wall washers.

Open-Plan Recessed Downlight Grid
Open-Plan Recessed Downlight Grid (Before)
BeforeAfter

Open-Plan Recessed Downlight Grid

Lay out recessed downlights in an even grid about 5 feet apart across the living, dining and kitchen, grouped into three dimmer zones.

House Reflected Ceiling Plan
House Reflected Ceiling Plan (Before)
BeforeAfter

House Reflected Ceiling Plan

Draw a monochrome reflected ceiling plan for this house with downlights, ceiling fans, a dining chandelier, cove lighting and ceiling heights.

Office Lighting with Lux Heatmap
Office Lighting with Lux Heatmap (Before)
BeforeAfter

Office Lighting with Lux Heatmap

Plan office lighting with linear LEDs over the desks and show a lux heatmap with about 500 lux at workstations.

Kitchen & Dining Lighting Design
Kitchen & Dining Lighting Design (Before)
BeforeAfter

Kitchen & Dining Lighting Design

Design kitchen and dining lighting with island pendants, a linear chandelier, under-cabinet and toe-kick LEDs and perimeter downlights.

Condo Lighting Plan to Night 3D Render
Condo Lighting Plan to Night 3D Render (Before)
BeforeAfter

Condo Lighting Plan to Night 3D Render

Show this condo lighting design as a night 3D isometric with warm downlights, island pendants, cove lighting and bedside lamps.

Lighting layer presets
6
Drawing styles incl. night 3D
3
Light level heatmaps
Lux
Print-ready resolution
2K

Capabilities

How Lighting Plan Generator preserves structure while elevating finishes

Every render locks structural geometry and natural lighting so materials and furnishings read accurately before remodeling.

A lighting plan with three layers, not one
01

A lighting plan with three layers, not one

A single ceiling fixture leaves rooms flat and corners dark. The lighting plan generator layers ambient, task and accent light in separate colors, so you see how each room works for cooking, reading and evenings.

Try this in the studio
Light levels you can read
02

Light levels you can read

Brightness is hard to judge from symbols alone. The lux heatmap layer shades each room by expected light level, around 500 lux at desks and counters, so dim spots show up before fixtures are ordered.

Try this in the studio
From lighting plan to night render
03

From lighting plan to night render

Clients rarely picture light from a drawing. Turn the same lighting plan into a night 3D render with warm pools of light from every planned fixture, ideal for design approvals.

Try this in the studio

Use Cases

Where designers & homeowners use it

Lighting designers

Lighting designers

Draft layered concepts and reflected ceiling plans quickly, then refine fixture specs for the final set.

Homeowners choosing fixtures

Homeowners choosing fixtures

See how many downlights, pendants and lamps each room needs before you shop.

Electricians and installers

Electricians and installers

Share a clear ceiling layout with switching zones so rough-in and fixture installs go smoothly.

Kitchen designers

Kitchen designers

Coordinate island pendants, under-cabinet strips and perimeter lights with cabinetry plans.

Office and retail fit-outs

Office and retail fit-outs

Check light levels at desks and displays with lux heatmaps before ordering fixtures.

Restaurants and hospitality

Restaurants and hospitality

Plan warm, layered ambiance and show owners a night render of the finished room.

Workflow

How Lighting Plan Generator works

Three steps from your drawing to a clean, presentation-ready 2K plan.

  1. 01

    Upload your floor plan

    Use a clean 2D plan with room labels as PNG, JPG or WebP up to 15 MB, and mention ceiling heights in the prompt for better fixture spacing.

  2. 02

    Choose a lighting layer and drawing style

    Generate a layered plan, downlight grid, reflected ceiling plan, lux heatmap, kitchen and dining design or smart zones, as color layers, a monochrome RCP or a night 3D render.

  3. 03

    Review, refine and share

    Compare the lighting plan with your floor plan, download the 2K sheet and use it to choose fixtures with your designer and wire them with your electrician.

How to Plan Layered Lighting Room by Room

Professional lighting plans build three layers. Ambient light fills the room evenly, usually from recessed downlights, flush fixtures or cove lighting. Task light puts brighter, focused light where you work: pendants over islands, under-cabinet strips at counters, vanity lights at mirrors and reading lamps by chairs. Accent light adds depth by washing walls, highlighting art and grazing textures. A lighting plan that shows all three in different colors makes gaps obvious.

Start with how each room is used, then size each layer. A common downlight starting point is spacing fixtures about half the ceiling height to the full ceiling height apart, depending on beam angle, and keeping the first row 2 to 3 feet from the walls so walls glow evenly. Put each layer on its own switch or dimmer so the room can shift from bright work light to a soft evening scene.

Architectural Circulation & Clearance StandardsReference Spec
Main Hallway Width36" to 42"
91 to 107 cm clear
Interior Door Opening32" to 36"
90° swing clearance
Dining Chair Pull-Back36" min
Table edge to wall
Sofa to Coffee Table16" to 18"
Ergonomic reach
Maintaining realistic circulation clearances and daylight openings ensures photorealistic renders remain buildable.
  • Pendants over an island: about 30 to 36 in above the counter, spaced about 24 to 30 in apart.
  • Dining chandelier: about 30 to 36 in above the table, roughly 12 in narrower than the table width.
  • Color temperature: 2700K to 3000K for warm living spaces, 3000K to 3500K for kitchens and work areas; aim for CRI 90 or higher.
  • Wall washers: about 2 to 3 ft from the wall they light.

Recommended Light Levels (Lux) for Your Lighting Plan

Illuminance is measured in lux (lumens per square meter) or foot-candles (lumens per square foot; 1 foot-candle is about 10.76 lux). Lighting guidance such as IES recommendations and the EN 12464-1 standard gives target ranges by task, and the lux heatmap layer uses them to color each room. Treat them as ranges: older eyes need more light, and dark finishes absorb more of it.

For a quick sizing check, multiply the room area in square meters by the target lux to estimate the lumens that must reach the room. A 12 by 15 foot living room is about 16.7 square meters, so 150 lux of ambient light needs about 2,500 lumens delivered; after typical losses that is roughly five or six 700 lumen downlights.

  • Living rooms and bedrooms, ambient: about 100 to 300 lux.
  • Kitchen counters and food prep: about 300 to 750 lux.
  • Desks and reading: about 300 to 500 lux; offices commonly target 500 lux at the work plane (EN 12464-1).
  • Hallways and stairs: about 50 to 150 lux.
  • Bathroom vanities: about 300 to 500 lux on the face, lit from the sides or front of the mirror.

Reflected Ceiling Plans, Controls and Coordination

A reflected ceiling plan (RCP) shows the ceiling as if you were looking down at it through a mirrored floor, so fixtures line up exactly with the walls below. It is where lighting meets everything else on the ceiling: HVAC diffusers, smoke alarms, speakers, sprinklers and access panels. Generating an RCP from your floor plan early helps keep downlights clear of joists and ducts and aligned with furniture.

Treat the AI lighting plan as a design concept. Your lighting designer or electrician confirms fixture specs, circuit loads, dimmer compatibility and the energy code your area enforces, which in many places calls for high-efficacy LED fixtures and occupancy or vacancy sensors in certain rooms.

Frequently asked questions

Clear answers on structural preservation, commercial downloads, private vaults, and credits.

Upload a photo above

What is a lighting plan?

A lighting plan is a floor plan or ceiling plan that shows where each light fixture goes, what type it is, which switch or dimmer controls it and how lighting is layered across rooms, usually with a legend of fixture symbols.

What is the difference between a lighting plan and a reflected ceiling plan?

A lighting plan focuses on fixtures, layers and controls. A reflected ceiling plan shows everything on the ceiling as seen from below, including lights, fans, vents, smoke alarms and ceiling heights. The lighting plan generator can produce both.

How far apart should recessed lights be?

A common starting point is spacing downlights about half to the full ceiling height apart, so 4 to 8 feet on an 8 foot ceiling depending on beam angle and brightness, with the first row 2 to 3 feet from the walls.

How many lumens or lux does a room need?

Living areas typically need 100 to 300 lux of ambient light, kitchens 300 to 750 lux at the counters and desks 300 to 500 lux. Multiply room area in square meters by the target lux to estimate lumens, then add a margin for losses.

Can the lighting plan be used for installation?

Use it as a concept plan for choosing fixtures and discussing layouts. Your electrician confirms circuits, loads, dimmer compatibility and local energy code requirements before installation.

Can I see how the lighting will look at night?

Yes. Choose Night 3D Render as the drawing style to see the same layout as a 3D cutaway lit only by your planned fixtures.

Design your lighting plan in seconds

Upload a floor plan above and get layered lighting, ceiling plans or lux heatmaps with a clear legend, ready for your designer and electrician.

Start now