

Apartment Floor Plan to Layered Lighting Plan
Create a layered lighting plan for this apartment with ambient downlights, kitchen pendants, under-cabinet LEDs, vanity lights and accent wall washers.
Upload a floor plan and get a lighting plan that layers ambient, task and accent light room by room, with fixtures, switching zones and light levels you can actually read.


Before & After
Drag across each transformation to inspect structural fidelity, or load any instruction directly into the studio above.


Create a layered lighting plan for this apartment with ambient downlights, kitchen pendants, under-cabinet LEDs, vanity lights and accent wall washers.


Lay out recessed downlights in an even grid about 5 feet apart across the living, dining and kitchen, grouped into three dimmer zones.


Draw a monochrome reflected ceiling plan for this house with downlights, ceiling fans, a dining chandelier, cove lighting and ceiling heights.


Plan office lighting with linear LEDs over the desks and show a lux heatmap with about 500 lux at workstations.


Design kitchen and dining lighting with island pendants, a linear chandelier, under-cabinet and toe-kick LEDs and perimeter downlights.


Show this condo lighting design as a night 3D isometric with warm downlights, island pendants, cove lighting and bedside lamps.
Capabilities
Every render locks structural geometry and natural lighting so materials and furnishings read accurately before remodeling.

A single ceiling fixture leaves rooms flat and corners dark. The lighting plan generator layers ambient, task and accent light in separate colors, so you see how each room works for cooking, reading and evenings.
Try this in the studio
Brightness is hard to judge from symbols alone. The lux heatmap layer shades each room by expected light level, around 500 lux at desks and counters, so dim spots show up before fixtures are ordered.
Try this in the studio
Clients rarely picture light from a drawing. Turn the same lighting plan into a night 3D render with warm pools of light from every planned fixture, ideal for design approvals.
Try this in the studioUse Cases

Draft layered concepts and reflected ceiling plans quickly, then refine fixture specs for the final set.

See how many downlights, pendants and lamps each room needs before you shop.

Share a clear ceiling layout with switching zones so rough-in and fixture installs go smoothly.

Coordinate island pendants, under-cabinet strips and perimeter lights with cabinetry plans.

Check light levels at desks and displays with lux heatmaps before ordering fixtures.

Plan warm, layered ambiance and show owners a night render of the finished room.
Workflow
Three steps from your drawing to a clean, presentation-ready 2K plan.
Use a clean 2D plan with room labels as PNG, JPG or WebP up to 15 MB, and mention ceiling heights in the prompt for better fixture spacing.
Generate a layered plan, downlight grid, reflected ceiling plan, lux heatmap, kitchen and dining design or smart zones, as color layers, a monochrome RCP or a night 3D render.
Compare the lighting plan with your floor plan, download the 2K sheet and use it to choose fixtures with your designer and wire them with your electrician.
Professional lighting plans build three layers. Ambient light fills the room evenly, usually from recessed downlights, flush fixtures or cove lighting. Task light puts brighter, focused light where you work: pendants over islands, under-cabinet strips at counters, vanity lights at mirrors and reading lamps by chairs. Accent light adds depth by washing walls, highlighting art and grazing textures. A lighting plan that shows all three in different colors makes gaps obvious.
Start with how each room is used, then size each layer. A common downlight starting point is spacing fixtures about half the ceiling height to the full ceiling height apart, depending on beam angle, and keeping the first row 2 to 3 feet from the walls so walls glow evenly. Put each layer on its own switch or dimmer so the room can shift from bright work light to a soft evening scene.
Illuminance is measured in lux (lumens per square meter) or foot-candles (lumens per square foot; 1 foot-candle is about 10.76 lux). Lighting guidance such as IES recommendations and the EN 12464-1 standard gives target ranges by task, and the lux heatmap layer uses them to color each room. Treat them as ranges: older eyes need more light, and dark finishes absorb more of it.
For a quick sizing check, multiply the room area in square meters by the target lux to estimate the lumens that must reach the room. A 12 by 15 foot living room is about 16.7 square meters, so 150 lux of ambient light needs about 2,500 lumens delivered; after typical losses that is roughly five or six 700 lumen downlights.
A reflected ceiling plan (RCP) shows the ceiling as if you were looking down at it through a mirrored floor, so fixtures line up exactly with the walls below. It is where lighting meets everything else on the ceiling: HVAC diffusers, smoke alarms, speakers, sprinklers and access panels. Generating an RCP from your floor plan early helps keep downlights clear of joists and ducts and aligned with furniture.
Treat the AI lighting plan as a design concept. Your lighting designer or electrician confirms fixture specs, circuit loads, dimmer compatibility and the energy code your area enforces, which in many places calls for high-efficacy LED fixtures and occupancy or vacancy sensors in certain rooms.
Clear answers on structural preservation, commercial downloads, private vaults, and credits.
Upload a photo aboveA lighting plan is a floor plan or ceiling plan that shows where each light fixture goes, what type it is, which switch or dimmer controls it and how lighting is layered across rooms, usually with a legend of fixture symbols.
A lighting plan focuses on fixtures, layers and controls. A reflected ceiling plan shows everything on the ceiling as seen from below, including lights, fans, vents, smoke alarms and ceiling heights. The lighting plan generator can produce both.
A common starting point is spacing downlights about half to the full ceiling height apart, so 4 to 8 feet on an 8 foot ceiling depending on beam angle and brightness, with the first row 2 to 3 feet from the walls.
Living areas typically need 100 to 300 lux of ambient light, kitchens 300 to 750 lux at the counters and desks 300 to 500 lux. Multiply room area in square meters by the target lux to estimate lumens, then add a margin for losses.
Use it as a concept plan for choosing fixtures and discussing layouts. Your electrician confirms circuits, loads, dimmer compatibility and local energy code requirements before installation.
Yes. Choose Night 3D Render as the drawing style to see the same layout as a 3D cutaway lit only by your planned fixtures.
Upload a floor plan above and get layered lighting, ceiling plans or lux heatmaps with a clear legend, ready for your designer and electrician.
Start now